Equipment and Facilities
CAMI has a diversity of computer and digital imaging/analysis capabilities. The facility is hard-wired with category 6 ethernet which provides for its own local area gigabit network as well as providing access throughout the Miami University network and the Internet.
Equipment and Facilities
Digital images can be captured from a diversity of input sources including direct digitizing from:
- microscopes
- video cameras
- copystand dSLR cameras
- high-resolution film and flatbed scanners (prints and negatives)
Image manipulation/analysis software includes:
- Image Pro Plus
- Global Lab Imaging
- Adobe Photoshop
- Corel Presentations
- Corel Photopaint
- and others
In addition to being fully equipped for conventional specimen preparations, CAMI is specialized for cryo-preservation techniques. CAMI houses one of the few high-pressure freezing units in North America (Balzers HFP 010), a propane jet freezing unit (RMC MF7200), a slam freezer (Pelco "Gentleman Jim"), and an automated freeze-substitution system (Reichert CSAuto).
In addition, the facility has 26+ pieces of specimen preparation equipment.
A small library of journals and books is also available.
Scanning Electron Microscopes (SEM)
JEOL JSM-840A SEM
Electron Sources: Tungsten Hairpin Imaging Modes: Secondary Electron, Backscattered Electron Accelerating Voltages: 1.0-30 kV, 100ev Steps Working Distances: 8mm, 20mm, and 45mm Magnifications: 15x - 50,000x Image Recording:
Orion Digital Capture Interface: Fast and Slow Scan Polaroid 4" x 5" sheet camera NTSC Composite video output
EDAX Genesis 2000 Energy Dispersive x-ray microanalysis system
Zeiss Supra 35 VP FEG SEM
Electron Sources: Schottky Field Emission Imaging Modes: Secondary Electron (SE), Backscattered Electron (QBSD), VPSE, In-lens SE Accelerating Voltages: 0.1 - 30 kV by 0.01 kV steps Probe Current: 4 pA to 20nA Working Distances: 0.1 - 50mm Magnifications: 12x - 900,000x Stage: X=125mm, Y=100mm, Z=35mm, T=0 to 90 Image Recording: 512 x 384 to 3072 x 2304 pixels at 16-bit Bruker Quantax 100 Energy Dispersive x-ray microanalysis system HKL Channel 5 Electron Backscattered Diffraction System (EBSD)
Transmission Electron Microscopes (TEM)
JEOL JEM-2100 Analytical TEM/STEM
Electron Sources: Lab6 Accelerating Voltages: 70 to 200 kV Imaging Modes: Brightfield, Darkfield, SAD, STEM, EFTEM Specimen Stage: Motorized, SEG with ± 75º tilt Single & Double tilt holders Magnifications: 500x - 1,500,000X, GIF mag 16X Detectors:
Gatan Orius SC200D Camera(2K x 2K) JEOL BF STEM Detector Gatan HAADF STEM Detector Gatan GIF Tridiem 863 Post-Column Energy Filter EELS/EFTEM with 2Kx2K UltraScan 1000 FT camera Bruker Quantax 200 STEM XEDS System
JEOL JEM-1200EX II TEM
Electron Sources: Tungsten Hairpin & LaB6 Accelerating Voltages: 40 to 120 kV Imaging Modes: Brightfield, Darkfield, SAD Specimen Stage: SEG with ± 60º tilt Magnifications: 50x - 400,000X Bottom mounted SIA-L9C digital camera (11 megapixels), with MaxIm DL 5 software Image Recording: 3.25" x 4" sheet film
Light Microscopes
Zeiss LSM 710 Laser Scanning Confocal System
34-Channel spectral fluorescence and one transmitted Laser Illumination
405nm Laser Diode Argon Ion: 457nm, 488nm, 514nm 543nm Laser Diode 633nm Laser Diode
Optical Platform: AxioObserver Z1
Lenses:
10x/0.30 NA WD=5.20 20x/0.80 NA WD=0.55 40x/0.75 NA WD=0.71 40x/1.30 NA WD=0.21 60x/1.40 NA WD=0.19 40x/1.1 Water Corrected WD=0.62
DIC on all objectives X-Cite 120 PC Epi-Fluorescence Illumination 100 W Halogen Illuminator
Olympus FV500 Laser Scanning Confocal System
Four channel fluorescence and one transmitted Laser Illumination
405nm Laser Diode Argon Ion: 457nm, 488nm, 514nm Green He/Ne: 543.5nm Red He/Ne: 633nm
Optical Platform: Olympus IX-81
Lenses:
10x /0.2 NA 20x /0.70NA 40x /0.75NA 40x /1.30NA 60x / 1.40NA 100x / 1.40NA
X-Cite 100 Epi-Fluorescence Illumination 100 W Halogen Illuminator
Olympus IX-81 Deconvolution
10x /0.2 NA 20x /0.70 NA 40x /1.30 NA 60x /1.40 NA 100x /1.40 NA
Epi-Fluorescence Illumination Photometric HQ cooled CCD camera SlideBook Deconvolution software Dual AMD2400 PC with 4GB RAM
Arcturus XT-TI LCM Laser Capture Microdissection System
IR capture Laser (810nm) UV cutting Laser (355nm) Nikon Eclipse-Ti-E Microscope Base:
Objectives: 2X, 4X, 10X, 20x, 40X, 60X, 100x objectives Bright-field, Phase contrast, DIC Epi-Fluoresence: UV, Blue, Green, and Red
2560 x 1920; 5 MP, progressive scan interline color CCD
Olympus AX-70 Wide-field Multi-mode Microscope
Imaging Modes for both transmitted and reflected light: Brightfield, Darkfield, Phase Contrast, DIC, Polarized light, and epi-fluorescence Lenses: 2x /0.1NA, 4x /-, 10x /0.2NA, 20x /0.70NA, 40x /0.85NA, 60x /1.4NA, 100x /1.35NA (Iris) Illumination: 100 w Halogen, X-cite 120 LED lamp Image Recording:
Roper 4k cooled CCD(2048 x 2048 x 12-bit) Nikon D300 dSLR 12 MP RGB Nikon D50 sSLR 6 MP RGB 35mm film camera Javelin CCD video camera Digital Capture Interface
Olympus BX-61 Wide-field Materials Light Microscope
Imaging Modes for both transmitted and reflected light: Brightfield, Darkfield, DIC, Polarized light, and epi-fluorescence Lenses: 2x /0.1NA, 4x /-, 10x /0.25NA, 20x /0.40NA, 50x /0.75NA, 100x /0.9NA Illumination: 100 w Halogen, 105 w Hg lamp Image Recording:
Nikon D300 dSLR 12 MegaPixel RGB
Olympus SZX-12 Stereoscope System
Imaging Modes: Brightfield, Darkfield, Epi-Fluorescent, Oblique Illumination Lenses: 0.5x and 1.4x Magnification Range: Illumination: Trans-illumination, fiberoptic epi-illumination, Oblique illumination, Polarized illumination Image Recording:
Nikon D300 dSLR 12 MP RGB SONY CCD camera Digital Capture Interface
CAMI Equipment Reservation Scheduler
Please note that all CAMI equipment is subject to usage fees, which will be billed to the account on file monthly. Users are responsible for ensuring their account information is kept up to date. If you have questions about billing, please get in touch with Christy Perry-Owens (heinricc@miamioh.edu).
Contact
Contact Us
- Wei Li, Ph.D., Director Upham Hall 09 Oxford, OH 45056
- 513-529-0944
- liw9@miamioh.edu
Our Microscopes
To see the hourly rates for microscope use, please log in to the PPMS scheduler. You can see the hourly rates by clicking on the “Book” option at the top of the page and choosing a microscope. The rates will appear in the upper right corner of each microscope booking page. If it says N/A, there is no charge for using that microscope. Contact CAMI if you need help or have any questions