In this section Center for Advanced Microscopy and Imaging Equipment and Facilities

Equipment and Facilities

CAMI has a diversity of computer and digital imaging/analysis capabilities. The facility is hard-wired with category 6 ethernet which provides for its own local area gigabit network as well as providing access throughout the Miami University network and the Internet.

Equipment and Facilities

Digital images can be captured from a diversity of input sources including direct digitizing from:

  • microscopes
  • video cameras
  • copystand dSLR cameras
  • high-resolution film and flatbed scanners (prints and negatives)

Image manipulation/analysis software includes:

  • Image Pro Plus
  • Global Lab Imaging
  • Adobe Photoshop
  • Corel Presentations
  • Corel Photopaint
  • and others

In addition to being fully equipped for conventional specimen preparations, CAMI is specialized for cryo-preservation techniques. CAMI houses one of the few high-pressure freezing units in North America (Balzers HFP 010), a propane jet freezing unit (RMC MF7200), a slam freezer (Pelco "Gentleman Jim"), and an automated freeze-substitution system (Reichert CSAuto).

In addition, the facility has 26+ pieces of specimen preparation equipment.

A small library of journals and books is also available.

Scanning Electron Microscopes (SEM)

JEOL JSM-840A SEM

Electron Sources: Tungsten Hairpin Imaging Modes: Secondary Electron, Backscattered Electron Accelerating Voltages: 1.0-30 kV, 100ev Steps Working Distances: 8mm, 20mm, and 45mm Magnifications: 15x - 50,000x Image Recording:

Orion Digital Capture Interface: Fast and Slow Scan Polaroid 4" x 5" sheet camera NTSC Composite video output

EDAX Genesis 2000 Energy Dispersive x-ray microanalysis system

Zeiss Supra 35 VP FEG SEM

Electron Sources: Schottky Field Emission Imaging Modes: Secondary Electron (SE), Backscattered Electron (QBSD), VPSE, In-lens SE Accelerating Voltages: 0.1 - 30 kV by 0.01 kV steps Probe Current: 4 pA to 20nA Working Distances: 0.1 - 50mm Magnifications: 12x - 900,000x Stage: X=125mm, Y=100mm, Z=35mm, T=0 to 90 Image Recording: 512 x 384 to 3072 x 2304 pixels at 16-bit Bruker Quantax 100 Energy Dispersive x-ray microanalysis system HKL Channel 5 Electron Backscattered Diffraction System (EBSD)

Transmission Electron Microscopes (TEM)

JEOL JEM-2100 Analytical TEM/STEM

Electron Sources: Lab6 Accelerating Voltages: 70 to 200 kV Imaging Modes: Brightfield, Darkfield, SAD, STEM, EFTEM Specimen Stage: Motorized, SEG with ± 75º tilt Single & Double tilt holders Magnifications: 500x - 1,500,000X, GIF mag 16X Detectors:

Gatan Orius SC200D Camera(2K x 2K) JEOL BF STEM Detector Gatan HAADF STEM Detector Gatan GIF Tridiem 863 Post-Column Energy Filter EELS/EFTEM with 2Kx2K UltraScan 1000 FT camera Bruker Quantax 200 STEM XEDS System

JEOL JEM-1200EX II TEM

Electron Sources: Tungsten Hairpin & LaB6 Accelerating Voltages: 40 to 120 kV Imaging Modes: Brightfield, Darkfield, SAD Specimen Stage: SEG with ± 60º tilt Magnifications: 50x - 400,000X Bottom mounted SIA-L9C digital camera (11 megapixels), with MaxIm DL 5 software Image Recording: 3.25" x 4" sheet film

Light Microscopes

Zeiss LSM 710 Laser Scanning Confocal System

34-Channel spectral fluorescence and one transmitted Laser Illumination

405nm Laser Diode Argon Ion: 457nm, 488nm, 514nm 543nm Laser Diode 633nm Laser Diode

Optical Platform: AxioObserver Z1

Lenses:

10x/0.30 NA WD=5.20 20x/0.80 NA WD=0.55 40x/0.75 NA WD=0.71 40x/1.30 NA WD=0.21 60x/1.40 NA WD=0.19 40x/1.1 Water Corrected WD=0.62

DIC on all objectives X-Cite 120 PC Epi-Fluorescence Illumination 100 W Halogen Illuminator

Olympus FV500 Laser Scanning Confocal System

Four channel fluorescence and one transmitted Laser Illumination

405nm Laser Diode Argon Ion: 457nm, 488nm, 514nm Green He/Ne: 543.5nm Red He/Ne: 633nm

Optical Platform: Olympus IX-81

Lenses:

10x /0.2 NA 20x /0.70NA 40x /0.75NA 40x /1.30NA 60x / 1.40NA 100x / 1.40NA

X-Cite 100 Epi-Fluorescence Illumination 100 W Halogen Illuminator

Olympus IX-81 Deconvolution

10x /0.2 NA 20x /0.70 NA 40x /1.30 NA 60x /1.40 NA 100x /1.40 NA

Epi-Fluorescence Illumination Photometric HQ cooled CCD camera SlideBook Deconvolution software Dual AMD2400 PC with 4GB RAM

Arcturus XT-TI LCM Laser Capture Microdissection System

IR capture Laser (810nm) UV cutting Laser (355nm) Nikon Eclipse-Ti-E Microscope Base:

Objectives: 2X, 4X, 10X, 20x, 40X, 60X, 100x objectives Bright-field, Phase contrast, DIC Epi-Fluoresence: UV, Blue, Green, and Red

2560 x 1920; 5 MP, progressive scan interline color CCD

Olympus AX-70 Wide-field Multi-mode Microscope

Imaging Modes for both transmitted and reflected light: Brightfield, Darkfield, Phase Contrast, DIC, Polarized light, and epi-fluorescence Lenses: 2x /0.1NA, 4x /-, 10x /0.2NA, 20x /0.70NA, 40x /0.85NA, 60x /1.4NA, 100x /1.35NA (Iris) Illumination: 100 w Halogen, X-cite 120 LED lamp Image Recording:

Roper 4k cooled CCD(2048 x 2048 x 12-bit) Nikon D300 dSLR 12 MP RGB Nikon D50 sSLR 6 MP RGB 35mm film camera Javelin CCD video camera Digital Capture Interface

Olympus BX-61 Wide-field Materials Light Microscope

Imaging Modes for both transmitted and reflected light: Brightfield, Darkfield, DIC, Polarized light, and epi-fluorescence Lenses: 2x /0.1NA, 4x /-, 10x /0.25NA, 20x /0.40NA, 50x /0.75NA, 100x /0.9NA Illumination: 100 w Halogen, 105 w Hg lamp Image Recording:

Nikon D300 dSLR 12 MegaPixel RGB

Olympus SZX-12 Stereoscope System

Imaging Modes: Brightfield, Darkfield, Epi-Fluorescent, Oblique Illumination Lenses: 0.5x and 1.4x Magnification Range: Illumination: Trans-illumination, fiberoptic epi-illumination, Oblique illumination, Polarized illumination Image Recording:

Nikon D300 dSLR 12 MP RGB SONY CCD camera Digital Capture Interface

CAMI Equipment Reservation Scheduler

Please note that all CAMI equipment is subject to usage fees, which will be billed to the account on file monthly. Users are responsible for ensuring their account information is kept up to date. If you have questions about billing, please get in touch with Christy Perry-Owens (heinricc@miamioh.edu).

Contact

Our Microscopes

To see the hourly rates for microscope use, please log in to the PPMS scheduler. You can see the hourly rates by clicking on the “Book” option at the top of the page and choosing a microscope. The rates will appear in the upper right corner of each microscope booking page. If it says N/A, there is no charge for using that microscope. Contact CAMI if you need help or have any questions